Research Status on Ankle Rehabilitation Robot

Page: [104 - 124] Pages: 21

  • * (Excluding Mailing and Handling)

Abstract

Background: Ankle is an important bearing joint in the human body. Unreasonable exercise patterns and exercise intensity can cause ankle injuries. This will seriously affect patients’ daily life. With the increase in the number of patients, the labor intensity of doctors is increasing. Ankle rehabilitation robot can help doctors free themselves from repetitive tasks, which is, of more practical value.

Objective: To give a general summary of recent ankle rehabilitation robot and introduce the respective characteristics and development including structure type, drive type and rehabilitation training mode.

Methods: This paper investigates various representative studies related to the ankle rehabilitation robot. The structure type, drive type, rehabilitation training mode and applications situation of these ankle rehabilitation robot are discussed.

Results: The characteristics of different types of ankle rehabilitation robots are analyzed. This paper analyzes the main problems in its development. The solutions to the issues and the current and future research on ankle rehabilitation robot are discussed.

Conclusion: The ankle rehabilitation robots are classified into motor drive type, pneumatic artificial muscle and pneumatic cylinder drive type and others. Further improvements are needed in the aspects of mechanical design, safety, virtual reality, brain-computer interface, control strategies and algorithm of bio-syncretic mechanism system of ankle rehabilitation robot. More related patents about ankle rehabilitation robot need to be developed.

Keywords: Ankle rehabilitation robot, ankle rehabilitation training, drive type, linear cylinder drive, motor drive, pneumatic muscle drive type, rehabilitation principle.

[1]
Karime A, Osman HA, Eid M, Gueaieb W, Saddik AE. Capturing ankle benchmark kinematics using an interactive sensory wobble board. IEEE International Conference on Multimedia and Expo Workshops. San Jose, CA, USA July. 2013.
[http://dx.doi.org/10.1109/ICMEW.2013.6618438]
[2]
de Noronha M, Lay EK, McPhee MR, Mnatzaganiam G, Nunes GS. Ankle sprain has higher occurrence during the later parts of matches: Systematic review with meta-analysis. J Sport Rehabil 2018; 1-8.
[http://dx.doi.org/10.1123/jsr.2017-0279]
[3]
Dizon JMR, Reyes JJB. A systematic review on the effectiveness of external ankle supports in the prevention of inversion ankle sprains among elite and recreational players. J Sci Med Sport 2010; 13(3): 309-17.
[http://dx.doi.org/10.1016/j.jsams.2009.05.002]
[4]
Mauntel TC, Wikstrom EA, Roos KG, Djoko A, Dompier TP, Kerr ZY. The epidemiology of high ankle sprains in National Collegiate Athletic Association Sports. Am J Sports Med 2017; 45(9): 2156-63.
[http://dx.doi.org/10.1177/0363546517701428]
[5]
Li D. Trajectory planning and control of “BSMS” ankle rehabilitation robot. MS Dissertation, Yanshan University, QinHuangdao, China, June 2008.
[6]
Yeung MS, Chan KM, So CH, Yuan WY. An epidemiological survey on ankle sprain. Br J Sports Med 1994; 28(2): 112-6.
[http://dx.doi.org/10.1136/bjsm.28.2.112]
[7]
Qing M, Mingming Z, Congzhe W, Hongsheng L. Towards optimal platform-based robot design for ankle rehabilitation: The state of the art and future prospects. J Healthc Eng 2018; 2018: 1534247.
[http://dx.doi.org/10.1155/2018/1534247]
[8]
Liu YH. Analysis and design of an ankle rehabilitation robot with remote center. MS Dissertation, Yanshan University, QinHuangdao, China, April 2010.
[9]
Nurahmi L, Solichin M. Motion type of 3-RPS parallel manipulator for ankle rehabilitation device. 2017 International Conference on Advanced Mechatronics, Intelligent Manufacture, and Industrial Automation (ICAMIMIA). Surabaya, Indonesia October,. 2017.
[http://dx.doi.org/10.1109/ICAMIMIA.2017.8387561]
[10]
Ayas MS, Altas IH. A redundantly actuated ankle rehabilitation robot and its control strategies. 2016 IEEE Symposium Series on Computational Intelligence. Athens, Greece. December, 2016;
[http://dx.doi.org/10.1109/SSCI.2016.7850068]
[11]
Sha Y, Zhang SX, Liu ZJ, Tan LW, Wan YS, Deng JH, et al. Computerized 3D reconstruction of ligaments of lateral aspect of the ankle and subtalar joints. Chin J Anatomy 2001; 24(2): 106-9.
[http://dx.doi.org/10.1007/s00276-001-0111-1]
[12]
Muscular and skeletal anatomy of ankle and foot (anterior view). Available at: http://www.mendoza-massoer.dk/primal/primal_16.jpg
[13]
Guan GP, Guan HT, Wang L. Ligament injury and application and research of artificial ligaments. Prog Biomed Eng 2013; 34(4): 234-8.
[14]
Wang CB, Wang L, Qin J, Wu ZZ, Duan LH, Li ZQ, et al. Development of an ankle rehabilitation robot for ankle training. Proceeding of the 2015 IEEE International Conference on Information and Automation. Lijiang, China August. 2015.
[15]
Lu ZJ. Development of self-training ankle rehabilitation robot. MS Dissertation, South China University of Technology, Guangzhou, China, April 2016.
[16]
Yang DC. On the treatment and recovery training of ankle injury. J Changsha Univ 2002; 16(4): 90-1.
[17]
Guan GP, Meng Q, Niu WX, Wang L. Research progress of ankle sprains, protection and rehabilitation. J Med Biomech 2016; 31(1): 78-82.
[18]
Tao Q, Dong JW, Sun X, Li Y. Effect of passive stretch and isokinetic exercise on ankle joint function impairment. Chin J Rehab 1999; 14(2): 90-1.
[19]
Yu H. Development of wearable 3-DOF ankle-foot rehabilitation exoskeleton. MS Dissertation, Zhejiang University, Hangzhou, China, January 2012.
[20]
Wang YF, Mei ZY, Xu JL, Zhao GR. Kinematic design of a parallel ankle rehabilitation robot for sprained ankle physiotherapy. Proceedings of the 2012 IEEE International Conference on Robotics and Biomimetics. Guangzhou, China December. 2012.
[http://dx.doi.org/10.1109/ROBIO.2012.6491203]
[21]
Zhao GR, Wang YF, Fan SC, Liu GQ. An ankle rehabilitation device CN104068991 (2016).
[22]
Li JF, Li SC, Tao CJ, Ji R, Xu CH, Zhang ZJ. Parallel 2-UPS/RRR ankle rehabilitation mechanism and kinematic performance analysis. Robot 2016; 38(2): 144-53.
[23]
Li JF, Li SC. An ankle rehabilitation device CN105125380 (2017).
[24]
Li JF, Zhang ZQ, Fan JH, Ma CM, Liu DZ. A parallel active/passive ankle rehabilitation training device. CN103070757 (2014).
[25]
Li JF, Li DS, Shen BW, Zhang ZC. Kinematical performance analysis of a 3-/RRS spherical parallel mechanism for ankle rehabilitation. International Conference on Mechanical Engineering and Automation. Lijiang, China. 2015.
[26]
Li DS, Li JF, Wang S, Zhang QH. Analysis on 3-RRS mechanism for ankle rehabilitation and its kinematics. Mach Des Manuf 2015; 8: 4-8.
[27]
Li JF, Xu CH, Tao CJ, Ji R, Li SC, Zhang ZJ. A parallel ankle rehabilitation mechanism and its performance analysis based on 3-UPS/RRR. Acta Automatica Sinica 2016; 42(12): 1794-807.
[28]
Zhang D. A parallel ankle rehabilitation robot. CN104887452 2015.
[29]
Cao Y, Ge SY, Wang ZD, et al. A transmission mechanism for ankle rehabilitation robot. CN106983632 (2017).
[30]
Wang CZ, Fang YF, Yu RT, Guo S. An ankle rehabilitation device. CN103479502 (2015).
[31]
Wang CZ, Fang YF, Guo S, Zhou CC. Design and kinematic analysis of redundantly actuated parallel mechanisms for ankle rehabilitation. Robotica 2015; 33(2): 366-84.
[http://dx.doi.org/10.1017/S0263574714000241]
[32]
Wang CZ, Fang YF, Guo S, Chen YQ. Design and kinematical performance analysis of a 3-RUS/RRR redundantly actuated parallel mechanism for ankle rehabilitation. J Mech Robot 2013; 5(4): 041003.
[http://dx.doi.org/10.1115/1.4024736]
[33]
Wang CZ, Fang YF, Guo S. Multi-objective optimization of a parallel ankle rehabilitation robot using modified differential evolution algorithm. Chin J Mech Eng 2015; 28(4): 702-15.
[http://dx.doi.org/10.3901/CJME.2015.0416.062]
[34]
Wang CZ, Zhang Y. A parallel ankle rehabilitation device. CN106974805 (2017).
[35]
Wang CZ. Research on innovative structural design and application of parallel mechanisms with multi-rotational degrees of freedom. PhD Dissertation, Beijing Jiaotong University, Beijing, China, December 2015.
[36]
Wei ZL, Ye H, Li FY, Hu QG, Li ZM. A novel ankle rehabilitation robot and its control method. CN107050763 2017.
[37]
Wei ZL, Li FY, Ye H. Design and control of a novel ankle rehabilitation robot. Techn Automat Appl 2017; 36(8): 64-70.
[38]
Yao LG, Zeng SL, Xue PJ, Wang HL. An adjustable ankle rehabilitation device. CN103156756 (2013).
[39]
Yao LG, Liao ZW, Lu ZX, Zhang J. Nutation motion based trajectory planning for a novel hybrid ankle rehabilitation device. J Mech Eng 2018; 54(21): 33-40.
[http://dx.doi.org/10.3901/JME.2018.21.033]
[40]
Flores P, Viadero F. In New Trends in Mechanism and Machine Science: Zeng SL, Yao LG, Guo XN Kinematics Analysis and Verification on the Novel Reconfigurable Ankle Rehabilitation Robot Based On Parallel Mechanism. Springer International Publishing 2015; pp. 195-202.
[http://dx.doi.org/10.1007/978-3-319-09411-3]
[41]
Malosio M, Negri SP, Pedrocchi N, Vicentini F, Caimmi M, Tosatti LM. A spherical parallel three degrees-of-freedom robot for ankle-foot neuro-rehabilitation. 34th Annual International Conference of the IEEE EMBS. San Diego, California, USA August. 2012.
[42]
Malosio M, Caimmi M, Ometto M, Tosatti LM. Ergonomics and kinematic compatibility of PKankle, a fully-parallel spherical robot for ankle-foot rehabilitation. 5th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics. São Paulo, Brazil, August 2014
[43]
Enferadi J, Haghi OR. On the kinematics analysis of a novel spherical robot with unlimited rotation around an axis. Proceedings of the 3rd RSI International Conference on Robotics and Mechatronics. Tehran, Iran, October 2015.
[http://dx.doi.org/10.1109/ICRoM.2015.7367777]
[44]
Enferadi J, Shahi A. On the position analysis of a new spherical parallel robot with orientation applications. Robot Comput-Integr Manuf 2016; 37: 151-61.
[http://dx.doi.org/10.1016/j.rcim.2015. 09.004]
[45]
Ayas MS, Altas IH. Fuzzy logic based adaptive admittance control of a redundantly actuated ankle rehabilitation robot. Control Eng Pract 2017; 59: 44-54.
[http://dx.doi.org/10.1016/j.conengprac. 2016.11.015]
[46]
Ayas MS, Altas IH. A redundantly actuated ankle rehabilitation robot and its control strategies. IEEE Symposium Series on Computational Intelligence. Athens, Greece December. 2016.
[http://dx.doi.org/10.1109/SSCI.2016.7850068]
[47]
Rosado A, Melchor W, Valdes V, Gerardo L, Andres BO, Jose RA, et al. Passive rehabilitation exercises with an ankle rehabilitation prototype based in a robot parallel structure IEEE Lat Am T2017; 15(1): 48-56
[http://dx.doi.org/10.1109/TLA.2017.7827887]
[48]
Xu LM, Li QC, Zhang NB, Chen QH. Mobility, kinematic analysis, and dimensional optimization of new three-degrees-of freedom parallel manipulator with actuation redundancy. J Mech Robot 2017; 9(4): 041008.
[http://dx.doi.org/10.1115/1.4036517]
[49]
Li QC, Zhang NB, Wang FB. New indices for optimal design of redundantly actuated parallel manipulators. J Mech Robot 2017; 9(1): 011007.
[http://dx.doi.org/10.1115/1.4035126]]
[50]
Du YT, Li RQ, Li DH, Bai SP. An ankle rehabilitation robot based on 3-RRS spherical parallel mechanism. Adv Mech Eng 2017; 9(8): 168781401771811.
[http://dx.doi.org/10.1177/1687814017718112]
[51]
Zeng DX, Hu ZT, Hou YL, Su YL. Novel decoupled parallel mechanism for ankle rehabilitation and its optimization. J Mech Eng 2015; 51(9): 1-9.
[http://dx.doi.org/10.3901/JME.2015.09.001]
[52]
Sun TY, Yu ZL, Wang CB, Duan LH, Liu QQ, Lu ZJ, et al. Development of a new parallel mechanism with five degrees of freedom for ankle rehabilitation. The 6th Annual IEEE International Conference on Cyber Technology in Automation, Control and Intelligent Systems. Chengdu, China, June 2016
[http://dx.doi.org/10.1109/CYBER.2016.7574839]
[53]
Wei JJ, Chen HQ, Chen PF, Lu ZX, Wei CD, Hou AX, et al. Development of parallel mechanism with six degrees of freedom for ankle rehabilitation. The 6th Annual IEEE International Conference on Cyber Technology in Automation, Control and Intelligent Systems. Macau, China, October, 2016
[http://dx.doi.org/10.1109/ICARM.2016.7606945]
[54]
Nurahmi L, Solichin M, Harnany D, Kurnianwan A. Dimension synthesis of 3-RPS parallel manipulator with intersecting R-axes for ankle rehabilitation device. Proceedings of the 2017 18th International Conference on Advanced Robotics. Hong Kong, China July, 2017.
[http://dx.doi.org/10.1109/ICAR.2017.8023529]
[55]
Han YL, Yu JM, Song AG, Zhu SQ, Zhang HL, Wu ZL. Parallel robot mechanism for ankle rehabilitation. J Southeast Univ 2015; 45(1): 45-50.
[56]
Li Y, Yao LG. Simulation and verification on a novel ankle rehabilitation robot. 14th International Federation for the Promotion of Mechanism and Machine Science World Congress. Taipei, Taiwan, October,. 2015.
[57]
Zhang MM. A parallel ankle rehabilitation robot and its control method. CN105105970 (2017).
[58]
Zhang MM, Sheng B, Davies TC, Meng W, Xie SQ. Model based open-loop posture control of a parallel ankle assessment and rehabilitation robot. IEEE International Conference on Advanced Intelligent Mechatronics. Busan, Korea July 2015.
[http://dx.doi.org/10.1109/AIM.2015.7222709]
[59]
Zhu GL, Zeng XF, Zhang MM, Xie S, Meng W, Huang XL, et al. Robot-assisted ankle rehabilitation for the treatment of drop foot: a case study. 12th IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications. Auckland, New Zealand October 2016.
[http://dx.doi.org/10.1109/MESA.2016.7587130]
[60]
Meng W, Liu Q, Zhang MM, Ai QS, Xie SQ. Compliance adaptation of an intrinsically soft ankle rehabilitation robot driven by pneumatic muscles. IEEE International Conference on Advanced Intelligent Mechatronics. Munich, Germany July 2017.
[http://dx.doi.org/10.1109/AIM.2017.8013999]
[61]
Zhang MM, Cao JH, Zhu GL, Miao Q, Zeng XF, Xie SQ. Reconfigurable workspace and torque capacity of a compliant ankle rehabilitation robot (CARR). Robot Auton Syst 2017; 98: 213-21.
[http://dx.doi.org/10.1016/j.robot.2017.06.006]
[62]
Zhang MM, Xie SQ, Li XL, Zhu GL, Meng W, Huang XL, et al. Adaptive patient-cooperative control of a compliant ankle rehabilitation robot (CARR) with enhanced training safety. IEEE Trans Ind Electron 2018; 65(2): 1398-407.
[http://dx.doi.org/10.1109/TIE. 2017.2733425]
[63]
Meng W, Xie SQ, Liu Q, Lu CZ, Ai QS. Robust iterative feedback tuning control of a compliant rehabilitation robot for repetitive ankle training. IEEE/ASME Trans Mechatron 2017; 22(1): 173-84.
[http://dx.doi.org/10.1109/TMECH.2016.2618771]
[64]
Liu Q, Liu AM, Meng W, Ai QS, Xie SQ. Hierarchical compliance control of a soft ankle rehabilitation robot actuated by pneumatic muscles. Frontiers in Neurorobotics 2017; 11: 64.
[http://dx.doi.org/10.3389/fnbot.2017.00064]
[65]
Liu HT, Xiong K, Jia XY, Xie SL. A three degree of freedoms ankle rehabilitation device driven by pneumatic muscle. CN105943306 (2017).
[66]
Jamwal PK, Xie S, Aw KC. Design Analysis of a pneumatic muscle driven wearable parallel robot for ankle joint rehabilitation. Proceedings of 2010 IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications. QingDao, China july 2010.
[http://dx.doi.org/10.1177/0363546517701428/MESA.2010.5551990]
[67]
Jamwal PK, Hussain S, Ghayesh MH, Rogozina SV. Adaptive impedance control of parallel ankle rehabilitation robot. J Dyn Syst Meas Control 2017; 139(11): 111006.
[http://dx.doi.org/10.1115/ 1.4036560]
[68]
Jamwal PK, Hussain S. Design optimization of a cable actuated parallel ankle rehabilitation robot: a fuzzy based multi-objective evolutionary approach. J Intell Fuzzy Syst 2016; 31(3): 1897-908.
[http://dx.doi.org/10.3233/JIFS-16030]
[69]
Jamwal PK, Xie SQ, Tsoi YH, Aw KC. Forward kinematics modelling of a parallel ankle rehabilitation robot using modified fuzzy inference. Mech Mach Theory 2010; 45(11): 1537-54.
[http://dx.doi.org/10.1016/j.mechmachtheory.2010.06.017]
[70]
Jamwal PK, Hussain S, Ghayesh MH, Rogozina SV. Impedance control of an intrinsically compliant parallel ankle rehabilitation robot. IEEE Trans Ind Electron 2016; 63(6): 3638-47.
[http://dx.doi.org/10.1109/TIE.2016.2521600]
[71]
Jamwal PK, Xie SQ, Aw KC. Kinematic design optimization of a parallel ankle rehabilitation robot using modified genetic algorithm. Robot Auton Syst 2009; 57(10): 1018-27.
[http://dx.doi.org/ 10.1016/j.robot.2009.07.017]
[72]
Jamwal PK, Hussain S. Multicriteria design optimization of a parallel ankle rehabilitation robot: Fuzzy dominated sorting evolutionary algorithm approach. IEEE Trans Syst Man Cybern Syst 2016; 46(5): 589-97.
[http://dx.doi.org/10.1109/TSMC.2015.2478389]
[73]
Jamwal PK, Hussain S, Tsoi YH, Ghayesh MH, Xie SQ. Musculoskeletal modelling of human ankle complex: estimation of ankle joint moments. Clin Biomech (Bristol, Avon) 2017; 44: 75-82.
[http://dx.doi.org/10.1016/j.clinbiomech.2017.03.010]
[74]
Jamwal PK, Hussain S, Xie SQ. Review on design and control aspects of ankle rehabilitation robots. Disabil Rehabil Assist Technol 2015; 10(2): 93-101.
[http://dx.doi.org/10.3109/17483107. 2013.866986]
[75]
Hussain S, Jamwal PK, Ghayesh MH. State-of-the-art robotic devices for ankle rehabilitation: Mechanism and control review. Proc Inst Mech Eng H 2017; 231(12): 1224-34.
[http://dx.doi.org/10. 1177/0954411917737584]
[76]
Jamwal PK, Hussain S, Mirnasiri N, Ghayesh MH, Xie SQ. Tele-rehabilitation using in-house wearable ankle rehabilitation robot. Assist Technol 2018; 30(1): 24-33.
[http://dx.doi.org/10.1080/ 10400435.2016.1230153]
[77]
Jamwal PK, Hussain S, Xie SQ. Three-stage design analysis and multicriteria optimization of a parallel ankle rehabilitation robot using genetic algorithm. IEEE Trans Autom Sci Eng 2015; 12(4): 1433-46.
[http://dx.doi.org/10.1109/TASE.2014.2331241]
[78]
Cao HX. The dynamics modeling and simulation of anklerehabilitation parallel robot MS Dissertation, Huazhong University of Science and Technology, Wuhan, China May 2016.
[79]
Yonezawa T, Nomura K, Onodera T, Ichimura S, Mizoguchi H, Takemura H. Evaluation of venous return in lower limb by passive ankle exercise performed by PHARAD. 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015. Milan, Italy August. 2015.
[80]
Nomura K, Yonezawa T, Ogitsu T, Mizoguchi H, Takemura H. Development of Stewart platform type ankle-foot device for trip prevention support. 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015. Milan, Italy August. 2015.
[81]
Nomura K, Yonezawa T, Takemura H, Mizoguchi H. Development of six-DOF human ankle motion control device using Stewart platform structure for fall prevention. J Robot Mechatron 2016; 28(5): 654-63.
[http://dx.doi.org/10.20965/jrm.2016.p0654]
[82]
Rastegarpanah A, Saadat M, Borboni A, Stolkin R. Application of a parallel robot in lower limb rehabilitation: A brief capability study. 2016 International Conference on Robotics and Automation for Humanitarian Applications. Kerala, India December. 2016.
[http://dx.doi.org/10.1109/RAHA.2016.7931865]
[83]
Rastegarpanah A, Saadat M. Lower limb rehabilitation using patient data. Appl Bionics Biomech 2016; 2016: 2653915.
[http://dx.doi.org/10.1155/2016/2653915]
[84]
Rakhodaei H, Saadat M, Rastegarpanah A, Abdullah CZ. Path planning of the hybrid parallel robot for ankle rehabilitation. Robotica 2016; 34(1): 173-84.
[http://dx.doi.org/10.1017/ S0263574714001210]
[85]
Vallés M, Cazalilla J, Ángel V, Mata V, Álvaro P, Díazrodríguez MA. 3-PRS parallel manipulator for ankle rehabilitation: Towards a low-cost robotic rehabilitation. Robotica 2017; 35(10): 1939-57.
[http://dx.doi.org/10.1017/S0263574715000120]
[86]
Abu-Dakk FJ, Valera A, Escalera JA, Vallés M, Mata V, Abderrahim M. Trajectory adaptation and learning for ankle rehabilitation using a 3-PRS parallel robot. 8th International Conference on Intelligent Robotics and Applications. Portsmouth, United Kingdom August 2015.
[http://dx.doi.org/10.1007/978-3-319-22876-1_41]
[87]
Ruiz-Hidalgo NC, Blanco-Ortega A, Abúndez-Pliego A, Colín-Ocampo J, Arias-Montiel M. Design and control of a novel 3-DOF parallel robot. 2016 International Conference on Mechatronics, Electronics and Automotive Engineering. Cuernavaca, Morelos, Mexico November 2016.
[http://dx.doi.org/10.1109/ICMEAE.2016.021]
[88]
Tsoi YH, Xie SQ. Design and control of a parallel robot for ankle rehabilitation. 15th International Conference on Mechatronics and Machine Vision in Practice. Auckland, New Zealand December,. 2008; p. 4749585.
[89]
Zhou L, Meng W, Lu CZ, Liu Q, Ai QS. Bio-inspired design and iterative feedback tuning control of a wearable ankle rehabilitation robot. J Comput Inf Sci Eng 2016; 16(4): 041003.
[http://dx.doi.org/10.1115/1.4033900]
[90]
Meng W, Liu Q, Zhou ZD, Ai QS, Sheng B, Xie SQ. Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation. Mechatronics 2015; 31: 132-45.
[http://dx.doi.org/10.1016/j.mechatronics.2015.04.005]
[91]
Zhou JW. Research on trajectory planning and compliant control of lower limb rehabilitation robot. MS Dissertation, Wuhan University of Technology, Wuhan, China, April 2015.
[92]
Patoglu V. Reconfigurable ankle exoskeleton device US8366591 (2013).
[93]
Erdogan A, Satici AC, Patoglu V. Design of a reconfigurable force feedback ankle exoskeleton for physical therapy ASME/IFToMM International Conference on Reconfigurable Mechanisms and Robots London, United Kingdom, June, 2009. 400-8.
[94]
Erdogan A, Celebi B, Satici AC, Patoglu V. Assist on-ankle: A reconfigurable ankle exoskeleton with series-elastic actuation. Auton Robots 2017; 41(3): 743-58.
[http://dx.doi.org/10.1007/ s10514-016-9551-7]
[95]
Aggogeri F, Pellegrini N, Adamini R. Functional design in rehabilitation: Modular mechanisms for ankle complex. Appl Bionics Biomech 2016; 2016: 9707801.
[96]
Yu RT, Fang YF, Guo S. Design and kinematic performance analysis of a cable-driven parallel mechanism for ankle rehabilitation. Robot 2015; 37(1): 53-62.
[http://dx.doi.org/10.1155/2016/ 9707801]