Abstract
Background: This study performed a meta-analysis to compare the safety and efficacy
of argon plasma coagulation (APC) concerning suture (SUT) and surgery (SUR).
Methods: The One-Way tests were applied, with p <0.05 significant. The value of R2 was analyzed
(heterogeneity), and the risk of bias of articles was evaluated.
Results: A total of 34 studies were found, eight about APC, twenty about SUT, and six about SUR.
For the percentage of Weight Loss Regained (%WLR), the means for APC, SUT, and SUR were
19.39 ± 10.94, 26.06 ± 16.71, and 17.05 ± 9.85, and for success rate (%SR), the means were 89.75
± 16.75, 86.80 ± 11.44, and 76.00 ± 21.57, respectively with p >0.05, with R2 ≥ 50%.
Conclusion: The APC proved to be efficient and safe like the other techniques.
[3]
Hales CM, Carroll MD, Fryar CD, Ogden CL. Prevalence of obesity among adults and youth: United States, 2015–2016 NCHS data brief, no 288. Hyattsville, MD: National Center for Health Statistics 2017.
[4]
Brazilian association for the study of obesity and the metabolic syndrome. In: Brazilian obesity guidelines. (4th ed..), São Paulo: ABESO 2022.
[13]
Aly A. Argon plasma coagulation and gastric bypass – a novel solution to stomal dilation. Obes Surg 2009; 19: 788-90.
[15]
Balshem H. Grade guidelines: 3 ratng the quality of evidence. J Clin Epidemiol 2011; 64(4): 401-6.
[16]
Higgins J, Green S. Cochrane Handbook for Systematic Reviews of Interventions Version 510. The Cochrane Collaboration 2011.
[18]
Malick KJ. Clinical applications of argon plasma coagulation in endoscopy. Gastroenterol Nurs 2006; 29: 392-3.
[19]
Thompson CC. Peroral endoscopic reduction of dilated gastrojejunal anastomosis after Roux-en-Y gastric bypass: A possible new option for patients with weight regain. In: Surg Endosc. 2006; 20: pp. 1744-8.
[23]
Heylen AMF. The OTSC –Clip in revisional endoscopy against weight gain after bariatric gastric bypass surgery. Obes Surg 2011; 21: 1629-33.
[24]
Galvao Neto M, Rodriguez L, Zundel N, Ayala JC, Campos J, Ramos A. Endoscopic revision of Roux-en-Y gastric bypass stomal dilation with a suturing device: preliminary results of a first out-of United States series. Bariatric Times 2011; 8: 32-4.
[26]
Storek D, Grund, KE, Gronbach G, Farin G, Becker HD. Endoscopic argon gas coagulation--initial clinical experiences. Z Gastroenterol 1993; 31: 675-9.
[27]
Muller MK. Laparoscopic pouch resizing and redo of gastrojejunal anastomosis for pouch dilatation following gastric bypass. Obes Surg 2005; 15: 1089-95.
[28]
Flanagan L. Measurement of functional pouch volume following the gastric bypass procedure. Obes Surg 1996; 6: 38-43.
[30]
Schulman A, Chan WW, Thompson CC. Endoscopic suturing for failed gastric by-pass: Predictors of succes. AGA 2013; S-827: Mo1958.
[32]
Cambi MPC, Marchesini SD, Baretta GAP. Post-bariatric surgery weight regain: Evaluation of nutritional profile of candidate patients for endoscopic argon plasma coagulation. ABCD, arq. bras. cir. dig. Arq Bras Cir Dig 2015; 28(1): 40-3.
[33]
De Quadros LG, Neto MG, Marchesini JC, et al. Correction to: Endoscopic argon plasma coagulation Vs. Multidisciplinary evaluation in the management of weight regain after gastric bypass surgery: A randomized controlled trial with SHAM group. Obes Surg 2020; 30(8): 3260-2.
[53]