Selective Sensing Platform Utilizing Graphitized Multi-Walled Carbon Nanotubes for Monitoring of Ondansetron and Paracetamol

Page: [736 - 746] Pages: 11

  • * (Excluding Mailing and Handling)

Abstract

Background: Ondansetron and paracetamol are often co-administrated to prevent and treat nausea and vomiting caused by anaesthesia and to control postoperative pain. In addition, ondansetron is used as the first-line antiemetic in paracetamol overdose. Therefore, a selective and sensitive method for their simultaneous analysis is of great importance. The electroanalytical methods are highly sensitive and offer many possibilities for new sensor platform design. However, at present, no electroanalytical method for simultaneous determination of these drugs has been proposed.

Objective: The aim of this study was to develop a novel nanosensor for selective monitoring of ondansetron and paracetamol in pharmaceutical and biological samples without expensive and timeconsuming pretreatments.

Methods: The graphitized multi-walled carbon nanotubes embedded in a cation exchange polymer matrix were selected, among various surface functionalizations evaluated, to design a novel sensor. Based on its excellent sensing performance, the first electroanalytical method was developed for the rapid concurrent determination of investigated drugs.

Results: The scanning electron microscopy study showed an interlinked nanoporous network structure and a highly enlarged active surface. The developed sensor facilitated electron transfer in the oxidation of both drugs and tremendously enhanced the adsorption capacity for ondansetron, thus exhibiting a significant increase in drug responses and sensitivity. To obtain much sensitive response of investigated drugs, the effect of pH values of supporting electrolyte, dispersed nanomaterial amount, the cation exchange polymer concentration, drop-casting volume of nanocomposite suspension, accumulation potential and deposition time on the peak current was evaluated. The developed electroanalytical method was validated and the practical utility of the proposed nanosensor was tested.

Conclusion: The developed sensor is a promising sensing platform with a fast response time for analysis of ondansetron and paracetamol at very different concentration levels found in their fixeddose combination and human serum sample after recommended daily doses showing its potential usage in pharmaceutical quality control and clinical research.

Keywords: Ondansetron, paracetamol, voltammetry, graphitized multi-walled carbon nanotubes, serum, combined pharmaceutical dosage form.

Graphical Abstract

[1]
He, H.; Pham-Huy, L.A.; Dramou, P.; Xiao, D.; Zuo, P.; Pham-Huy, C. Carbon nanotubes: applications in pharmacy and medicine. BioMed Res. Int., 2013, 2013, 578290.
[http://dx.doi.org/10.1155/2013/578290] [PMID: 24195076]
[2]
Singh, B.; Lohan, S.; Sandhu, P.S.; Jain, A.; Mehta, S.K. Functionalized carbon nanotubes and their promising applications in therapeutics and diagnostics.Nanobiomaterials in Medical Imaging; Grumezescu, A.M., Ed.; Elsevier: Amsterdam, 2016, pp. 455-478.
[http://dx.doi.org/10.1016/B978-0-323-41736-5.00015-7]
[3]
Sinha, A. Dhanjai; Jain, R.; Zhao, H.; Karolia, P.; Jadon, N. Voltammetric sensing based on the use of advanced carbonaceous nanomaterials: a review. Mikrochim. Acta, 2018, 185(2), 89.
[http://dx.doi.org/10.1007/s00604-017-2626-0] [PMID: 29594390]
[4]
Kurbanoglu, S.; Ozkan, S.A. Electrochemical carbon based nanosensors: A promising tool in pharmaceutical and biomedical analysis. J. Pharm. Biomed. Anal., 2018, 147, 439-457.
[http://dx.doi.org/10.1016/j.jpba.2017.06.062] [PMID: 28780997]
[5]
Mallakpour, S.; Soltanian, S. Surface functionalization of carbon nanotubes: fabrication and applications. RSC Advances, 2016, 6, 109916-109935.
[http://dx.doi.org/10.1039/C6RA24522F]
[6]
Zhang, L.L.; Xu, F.F.; Feng, J.W. The influence of graphitization on the structure and electrical properties of carbon nanotubes. J. Inorg. Mater., 2009, 24, 535-538.
[http://dx.doi.org/10.3724/SP.J.1077.2009.00535]
[7]
Xue, Y.; Zheng, S.; Sun, Z.; Zhang, Y.; Jin, W. Alkaline electrochemical advanced oxidation process for chromium oxidation at graphitized multi-walled carbon nanotubes. Chemosphere, 2017, 183, 156-163.
[http://dx.doi.org/10.1016/j.chemosphere.2017.05.115] [PMID: 28544901]
[8]
Christofaki, M.; Papaioannou, A. Ondansetron: a review of pharmacokinetics and clinical experience in postoperative nausea and vomiting. Expert Opin. Drug Metab. Toxicol., 2014, 10(3), 437-444.
[http://dx.doi.org/10.1517/17425255.2014.882317] [PMID: 24471415]
[9]
Thanacoody, H.K.; Gray, A.; Dear, J.W.; Coyle, J.; Sandilands, E.A.; Webb, D.J.; Lewis, S.; Eddleston, M.; Thomas, S.H.; Bateman, D.N. Scottish and Newcastle antiemetic pre-treatment for paracetamol poisoning study (SNAP). BMC Pharmacol. Toxicol., 2013, 14, 20.
[http://dx.doi.org/10.1186/2050-6511-14-20] [PMID: 23556549]
[10]
Bhosale, U.A.; Khobragade, R.; Naik, C.; Yegnanarayan, R.; Kale, J. Randomized, double-blind, placebo-controlled study to investigate the pharmacodynamic interaction of 5-HT3 antagonist ondansetron and paracetamol in postoperative patients operated in an ENT department under local anesthesia. J. Basic Clin. Physiol. Pharmacol., 2015, 26(3), 217-222.
[http://dx.doi.org/10.1515/jbcpp-2014-0070] [PMID: 25324445]
[11]
Martin, S.; Baines, D.; Holtby, H.; Carr, A.S. Guidelines on the prevention of post-operative vomiting in children; The Association of Paediatric Anaesthetists of Great Britain and Ireland, 2016.
[12]
Jenkinson, E.; Langford, N. Best evidence topic reports. Bet 2. Should ondansetron be used as the first-line anti-emetic in paracetamol overdose? Emerg. Med. J., 2008, 25(2), 104-105.
[http://dx.doi.org/10.1136/emj.2007.056655] [PMID: 18212150]
[13]
Espinosa Bosch, M.; Riuz Sánchez, A.J.; Sánchez Rojas, F.; Bosch Ojeda, C. Review of analytical methodologies for the determination of 5-HT3 receptor antagonists. Microchem. J., 2017, 132, 341-350.
[http://dx.doi.org/10.1016/j.microc.2017.02.023]
[14]
Montaseri, H.; Forbes, P.B.C. Analytical techniques for the determination of acetaminophen: A review. TrAC. Trends Analyt. Chem., 2018, 108, 122-134.
[http://dx.doi.org/10.1016/j.trac.2018.08.023]
[15]
Suneetha, A.; Chandana Priya, T. RP-HPLC method for simultaneous estimation of paracetamol and ondansetron in bulk and oral suspension. J. Pharm. Res., 2014, 13, 106-110.
[http://dx.doi.org/10.18579/jpcrkc/2014/13/4/78375]
[16]
Jadon, N.; Jain, R.; Sharma, S.; Singh, K. Recent trends in electrochemical sensors for multianalyte detection - A review. Talanta, 2016, 161, 894-916.
[http://dx.doi.org/10.1016/j.talanta.2016.08.084] [PMID: 27769500]
[17]
Nigović, B.; Sadiković, M.; Sertić, M. Multi-walled carbon nanotubes/Nafion composite film modified electrode as a sensor for simultaneous determination of ondansetron and morphine. Talanta, 2014, 122, 187-194.
[http://dx.doi.org/10.1016/j.talanta.2014.01.026] [PMID: 24720982]
[18]
Varchenko, V.V.; Strilets, D.V.; Belikov, K.N. Determination of ondasetron at a carbon paste electrode by derivative voltammetry. Methods Objects Chem. Anal., 2014, 9, 139-144.
[http://dx.doi.org/10.17721/moca.2014.139-144]
[19]
Zaabal, M.; Doulache, M.; Bakirhan, N.K.; Kaddour, S.; Saidat, B.; Ozkan, S.A. A facile strategy for construction of sensor for detection of ondansetron and investigation of its redox behavior and thermodynamic parameters. Electroanal., 2019, 31, 1279-1290.
[http://dx.doi.org/10.1002/elan.201800658]
[20]
Cernat, A.; Tertiş, M.; Săndulescu, R.; Bedioui, F.; Cristea, A.; Cristea, C. Electrochemical sensors based on carbon nanomaterials for acetaminophen detection: A review. Anal. Chim. Acta, 2015, 886, 16-28.
[http://dx.doi.org/10.1016/j.aca.2015.05.044] [PMID: 26320632]
[21]
Niedziałkowski, P.; Cebula, Z.; Malinowska, N.; Białobrzeska, W.; Sobaszek, M.; Ficek, M.; Bogdanowicz, R.; Anand, J.S.; Ossowski, T. Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls. Biosens. Bioelectron., 2019, 126, 308-314.
[http://dx.doi.org/10.1016/j.bios.2018.10.063] [PMID: 30445306]
[22]
Nasrin, R.; Reza, S.M. Synthesis and characterization of an Au nanoparticles/graphene nanosheet nanocomposite and its application for the simultaneous determination of tramadol and acetaminophen. Anal. Methods, 2019, 11, 5150-5159.
[http://dx.doi.org/10.1039/C9AY01497G]
[23]
Liu, W.; Shi, Q.; Zheng, G.; Zhou, J.; Chen, M. Electrocatalytic oxidation toward dopamine and acetaminophen based on AuNPs@TCnA/GN modified glassy carbon electrode. Anal. Chim. Acta, 2019, 1075, 81-90.
[http://dx.doi.org/10.1016/j.aca.2019.05.031] [PMID: 31196426]
[24]
Murugan, E.; Kumar, K. Fabrication of SnS/TiO2@GO composite coated glassy carbon electrode for concomitant determination of paracetamol, tryptophan, and caffeine in pharmaceutical formulations. Anal. Chem., 2019, 91(9), 5667-5676.
[http://dx.doi.org/10.1021/acs.analchem.8b05531] [PMID: 30946567]
[25]
de Wit, R.; Beijnen, J.H.; van Tellingen, O.; Schellens, J.H.; de Boer-Dennert, M.; Verweij, J. Pharmacokinetic profile and clinical efficacy of a once-daily ondansetron suppository in cyclophosphamide-induced emesis: a double blind comparative study with ondansetron tablets. Br. J. Cancer, 1996, 74(2), 323-326.
[http://dx.doi.org/10.1038/bjc.1996.361] [PMID: 8688345]
[26]
Bannwarth, B.; Péhourcq, F. [Pharmacologic basis for using paracetamol: pharmacokinetic and pharmacodynamic issues]. Drugs, 2003, 63(Spec No 2), 5-13.
[http://dx.doi.org/10.2165/00003495-200363992-00003] [PMID: 14758786]
[27]
Nigović, B.; Sadiković, M.; Jurić, S. Electrochemical sensing of mesalazine and its N-acetylated metabolite in biological samples using functionalized carbon nanotubes. Talanta, 2016, 147, 50-58.
[http://dx.doi.org/10.1016/j.talanta.2015.09.036] [PMID: 26592575]
[28]
Lewis, D.F.; Ito, Y.; Eddershaw, P.J.; Dickins, M.; Goldfarb, P.S. An evaluation of ondansetron binding interactions with human cytochrome P450 enzymes CYP3A4 and CYP2D6. Drug Metab. Lett., 2010, 4(1), 25-30.
[http://dx.doi.org/10.2174/187231210790980408] [PMID: 20201779]
[29]
Xiong, H.; Xu, H.; Wang, L.; Wang, S. Characterization and sensing properties of a carbon nanotube paste electrode for acetaminophen. Mikrochim. Acta, 2009, 167, 129-133.
[http://dx.doi.org/10.1007/s00604-009-0235-2]
[30]
International Conference on Harmonization (ICH) Validation of Analytical Procedures: Text and Methodology Q2 (R1). 2005.